MP-1xx/H.323 User’s Manual 6. Provisioning
Version 4.2 Beta 77 June 2003
Table 6-4: Call Progress Tones Template (continues on pages 74 to 77)
First Signal On Time [10msec]=0
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=10
Second Signal Off Time [10msec]=10
#Hold Tone
[CALL PROGRESS TONE #8]
Tone Type=23
Low Freq [Hz]=1400
High Freq [Hz]=0
Low Freq Level [-dBm]=15
High Freq Level [-dBm]=32
First Signal On Time [10msec]=0
First Signal Off Time [10msec]=0
Second Signal On Time [10msec]=40
Second Signal Off Time [10msec]=500
6.4.3 Format of the Ringing Definition
The ringing pattern configures the ringing tone frequency and up to 4 ringing cadences. It is
applicable for the MP-1xx/FXS Gateways. Only single ringing pattern can be defined, if not a
default ringing pattern applies. The ringing frequency can be configured in the range from 10 Hz
up to 200 Hz with a 5 Hz resolution. Each ringing cadence period can be defined as single ringing
burst. Refer to the examples below.
The distinctive ringing section of the ini file format contains the following strings:
[NUMBER OF DISTINCTIVE RINGING PATTERNS]
" Number of Ringing patterns = 1
" [Ringing Pattern #0]
" Ring Type =0
" Freq [Hz] – Frequency in hertz of the ringing tone.
" First Ring On Time [10 msec] – “Ring On” period (in 10 msec units) for the first cadence
on-off cycle.
" First Ring Off Time [10 msec] – “Ring Off” period (in 10 msec units) for the first cadence
on-off cycle.
" Second Ring On Time [10 msec] – “Ring On” period (in 10 msec units) for the second
cadence on-off cycle.
" Second Ring Off Time [10 msec] – “Ring Off” period (in 10 msec units) for the second
cadence on-off cycle.
" Third Ring On Time [10 msec] – “Ring On” period (in 10 msec units) for the third cadence
on-off cycle.
" Third Ring Off Time [10 msec] – “Ring Off” period (in 10 msec units) for the third cadence
on-off cycle.