SIP User's Manual 302 Document #: LTRT-65408
Coefficients checksum.
Message waiting indication status.
Ring state.
Reversal polarity state.
Line current (only on port 0).
Line voltage between TIP and RING (only on port 0).
3.3 V reading (only on port 0).
Ring voltage (only on port 0).
Long line current (only on port 0).
The following line tests are available on FXO gateways:
Hardware revision number.
Hook state.
Reversal polarity state.
¾
To perform analog line testing using the embedded Web server,
take these 2 steps:
1. Click the Analog Line Testing submenu (Status & Diagnostics menu > Analog
Line Testing); the Analog Line Testing confirmation box is displayed.
Figure 13-1: Analog Line Testing Confirmation Box
2. Click OK to confirm that you want to continue start the test; the 'FXS Line Testing For
Channel 1' screen appears.
Figure 13-2: FXS Line Testing For Channel 1 Screen
To perform the test again, click the ReTest button.