Configuring Analog Extensions with AudioCodes Gateways Page 16 of 25
17. Select VoIP > GW and IP to IP > Analog Gateway > Caller ID Permissions. Enable for Caller ID for all ports.
Figure 23: Enable Caller ID
18. Select VoIP > GW and IP to IP > Analog Gateway > Authentication. Configure the entry Port 1 FXS as fol-
lows:
Figure 24: Configure authentication settings
Set User Name to 167.
For the password, enter 5656.
(This is the extension and password you set up on page 4.)